| BASIC CONCEPT: |
| The Fire Strobe 2000 is received optically by
line of sight. The range varies with the ambient light and intensity of the strobe
emitter. A typical range varies from 150 feet to 500 feet. The detector will not
allow false operation with unwanted signals from radio interference, and/or flashing
headlights or loud sounds. The acquisition time from the emitter light source and the discriminate module is approximately .5 seconds. The Fire Strobe 2000 is widely used for security/electric
gate access. It can be used for firehouse garage doors, and other related access needed
for emergency vehicles This emergency vehicle strobe detector provides rapid access
to any gated community that has been serviced by fire and emergency equipment on the
OPTICOM Strobe System.( of 3M). |
| FEATURES: |
| Rapid Detection Of Any Emergency Strobe |
|
| Field Programmable |
|
| Ease of Installation |
|
| INSTALLATION & TESTING |
| Complete Installation Instructions are provided with
the Fire Strobe 2000 for simple hook-up of the unit to interface with your gate or access
control. Two dry contacts are also provided for bi-directional operation where needed. The photoeye is typically mounted 8 to 10 feet above street level and is aimed for optimal strobe signal. [A total of (2) photoeye assemblies may be used]. A 12 VAC power supply is provided with the Fire Strobe 2000 system. Testing can be accomplished with the optional fire strobe
transmitter tester. This Fire Strobe 2000 transmitter will enable a throughput of signals
from the photoeye assembly to the relay output. This is a hand-held transmitter which
operates via 9-volt battery. The transmitter tester has a limited range of 6" and
must be held up to the photoeye assembly during the test phase. |
| TECHNICAL SPECIFICATIONS |
|
| WARRANTY |
| The Fire Strobe 2000 has a 1 year warranty when used according to the manufacturer's specifications. This warranty does not apply when the Fire Strobe 2000 has been abused, over voltaged, or altered in any way. The warranty coverage is at the sole discretion of the manufacturer. This unit is to be used only for the operations described above. |
|