Model 28SA-PLUS Slotless Card Reader Specifications
Surface Mount Housing
Lexan Surface Housing
PHYSICAL   Surface Housing
  Depth 2.25 in (5.72 cm)
  Width 4.00 in (10.16 cm)
  Height 4.60 in (11.70 cm)
  Weight 17 oz (0.57kg)
  Material Lexan (polycarbonate) meets UL standard 94 flame retardant rating
  Color Beige
POWER REQUIREMENTS Without Remote Reader
12 to 24 VAC or VDC, 125 mA
With Remote Reader (SK-029W)
12 to 16 VAC or VDC, 250 mA
OUTPUTS Latch & Alarm Shunt
DPDT contact, 3A, 125 to 277 VAC or 30 VDC
Tamper (optional)
SPDT contact, 115 AC, 2A maximum
INPUTS Auxiliary 1 (Door Monitor)
Requires SPST contact closure
Auxiliary 2 (Disabled)
Requires SPST contact closure
*Factory Default - can be changed via PC
Auxiliary 3 (Disabled
Requires SPST contact closure
*Factory Default - can be changed via PC
COMMUNICATION RS-232 (5-wire Shielded Cable)
Serial RS-232. Up to 38.4K Baud, full duplex, (8N1)
RS-485 (Single Twisted Pair)
Built-in Network Module
Remote Reader
31 bit or 26 bit  Wiegand type input, 10-21 VDC @ 150 mA supplied to remote reader,depending on inpt voltage supplied to 28SA PLUS
Modem
Requires Hayes compatible - 1.2 to 38.4k baud
LAN
Requires external device server
Printer
Serial Printer (or Parallel printer with serial converter)
ENVIRONMENT Ambient Temperature
-40o F to 158o F  (-40 C to 70 C)
Humidity
0% to 95% relative humidity (non condensing)
OPERATIONAL Memory
Non-Volatile (Programming retained, even if power is lost)
Card Capacity
65,000 sequentially numbered cards
Limited Use Cards
4,000 programmable from 1-500 uses, days, weeks
Transaction Storage
5000 events
Time Zones
15 for card access, 1 door unlock time zone; full week plus holiday in one-half hour segments; 32 programmable holidays; selectable automatic daylight saving time.
Facility Code
Up to 3 different codes simultaneously. (Max. # of cards 65,000)
Latch/Alarm Shunt Timer
Programmable from 1/4 to 30 seconds
Antipassback
Real or Timed from (1 to 30 minutes);  hard or soft
Auxillary Inputs (3)
Programmable for door monitor, tamper monitor, remote open, remote inactive, bell, arming circuit or user defined
PROGRAMMING
PD-26 Programming Deck

This Product Complies with UL 294 Standards, CE (European Standards), and with Part 15 of Class B of the FCC rules.