The EMX LRS Direct Burial Probe Magnetoresistive Sensor is designed to be paired with the LRS-C1 Control Unit. The LRS-DB sensor stores ambient background and settings in the non-volatile memory. The self contained unit is ideal for above ground installations.
LRS Specifications (PDF)
| Outputs | NPN (Open Collector) |
| Output Ratings | 50 mA |
| Connection | 5 Conductor Direct Burial |
| Housing | Direct Burial (-DB): PVC |
| Environmental Rating | IP69K |
| Power Supply | 12-30 VDC |
| Current Draw | 10 mA Max |
| Dimensions | Direct Burial (-DB): 4.0" (102mm) x 1.0" (27mm) |
| Weight | Direct Burial (-DB): 0.09 lbs. (43g) |
| Sensing Technology | 3-Axis Magnetoresistive |
| Sensitivity | 10 Levels: 0-9 |
| Axis Sensitivity | 512 Counts/Gauss (Typical) |
| Environmental Tracking | Automatic Compensation |
| Local Magnetic Field Nulling | Averages local field signature in any sensor orientation |
| Detection Range | 5 ft. (1.5m) |
| Pulse/Presence | Allows the relay/NPN output to send either a pulse output or have constant presence |
| Detect-On-Stop | Requires vehicle to stop for a minimum of 1 second (1-2s typical) |
| Operating Environment | -40°F to 180°F (-40°C to 82°C) |
| Supply Protection Circuitry | Reverse Polarity and Fuse Protected |
LRS Instructions (PDF)
There are no reviews yet. Be the first to Write a Review (requires login).